{"product_id":"avalux-28kw-inverter-heat-pump-three-phase","title":"Avalux 28kW Inverter Heat Pump - Three Phase","description":"\u003ch2\u003e\u003cstrong\u003eAvalux 28kW Inverter Heat Pump - Three Phase\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eThe 28kW, wired for three phase.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe same 27.7kW output as the single-phase 28, wired for 400V three phase. The practical difference is current: 7.3 amps per phase against 20.8, which makes the install easier and the supply far less stressed. If you have three phase at the board, take this one.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFull DC inverter compressor and fan - runs long and slow instead of cycling\u003c\/li\u003e\n\u003cli\u003eR32 refrigerant, lower global warming potential than R410A\u003c\/li\u003e\n\u003cli\u003eHeating and cooling, with an operating range down to -7C\u003c\/li\u003e\n\u003cli\u003eTitanium heat exchanger with a 40mm water connection\u003c\/li\u003e\n\u003cli\u003eIPX4 rated for outdoor installation\u003c\/li\u003e\n\u003cli\u003eDigital controller with water temperature display\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eAL28T\u003c\/th\u003e\n\u003cth\u003eUnit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity (air 27C \/ water 26C)\u003c\/td\u003e\n\u003ctd\u003e5.2 ~ 27.7\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumed power (air 27C \/ water 26C)\u003c\/td\u003e\n\u003ctd\u003e0.38 ~ 3.9\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP (air 27C \/ water 26C)\u003c\/td\u003e\n\u003ctd\u003e16.4 ~ 7.0\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity (air 15C \/ water 26C)\u003c\/td\u003e\n\u003ctd\u003e6.0 ~ 20.3\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumed power (air 15C \/ water 26C)\u003c\/td\u003e\n\u003ctd\u003e0.75 ~ 3.8\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP (air 15C \/ water 26C)\u003c\/td\u003e\n\u003ctd\u003e8.0 ~ 5.3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity (air 35C \/ water 29C)\u003c\/td\u003e\n\u003ctd\u003e5.5 ~ 13.5\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumed power (air 35C \/ water 29C)\u003c\/td\u003e\n\u003ctd\u003e1.66 ~ 4.65\u003c\/td\u003e\n\u003ctd\u003ekW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER (air 35C \/ water 29C)\u003c\/td\u003e\n\u003ctd\u003e3.3 ~ 2.9\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating air temperature\u003c\/td\u003e\n\u003ctd\u003e-7 ~ 43\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIPX rating\u003c\/td\u003e\n\u003ctd\u003eIPX4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAirflow\u003c\/td\u003e\n\u003ctd\u003e4275\u003c\/td\u003e\n\u003ctd\u003em3\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure at 1m\u003c\/td\u003e\n\u003ctd\u003e45 ~ 57\u003c\/td\u003e\n\u003ctd\u003edB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet dimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e1160 x 490 x 862\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping dimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e1210 x 510 x 880\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet \/ shipping weight\u003c\/td\u003e\n\u003ctd\u003e103 \/ 120\u003c\/td\u003e\n\u003ctd\u003ekg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e400\/3\/50\u003c\/td\u003e\n\u003ctd\u003eV\/Ph\/Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax run current (per phase)\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan direction\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan rotate speed\u003c\/td\u003e\n\u003ctd\u003e400 ~ 800\u003c\/td\u003e\n\u003ctd\u003eRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater connection\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003emm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater flow volume\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003ctd\u003eL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater pressure drop (max)\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003ekPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003eInstallation must be carried out by a licensed electrician and, where required, a licensed plumber. This model requires a 400V three-phase supply.\u003c\/em\u003e\u003c\/p\u003e","brand":"Avalux","offers":[{"title":"Default Title","offer_id":67646577868974,"sku":"AL28T","price":16445.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0586\/3827\/0638\/files\/avalux-large-front_7b594623-f46d-43b9-81be-400015a5330a.png?v=1791859927","url":"https:\/\/www.loopym.com.au\/products\/avalux-28kw-inverter-heat-pump-three-phase","provider":"Loopym","version":"1.0","type":"link"}